Just added to your cart

Continue shopping

Single wall round flue system T600

AKVILON
In stock
24.47
20.22 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
14.68
12.13 € Without VAT
pluss minuss
AKVILON
In stock
8.08
6.68 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
13.29
10.98 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
26.60
21.98 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
17.77
14.69 € Without VAT
pluss minuss
Flue T-piece 90° - D-80
code: dvpv90080
AKVILON
In stock
32.09
26.52 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
38.20
31.57 € Without VAT
pluss minuss
Flue T-piece 45° - D-80
code: dvpv45080
AKVILON
production 2-7 working days
34.74
28.71 € Without VAT
pluss minuss
Revision T-piece - D-80
code: dvtv0080
AKVILON
production 2-7 working days
42.75
35.33 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
57.48
47.50 € Without VAT
pluss minuss
Flue inspection door - 120x180
code: dvkj23/120x180
AKVILON
delivery: 5-10 working days
23.96
19.80 € Without VAT
pluss minuss
AKVILON
In stock
16.63
13.74 € Without VAT
pluss minuss
AKVILON
In stock
11.98
9.90 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
30.73
25.40 € Without VAT
pluss minuss
Flue bottom cap - D-80
code: dvnva080
AKVILON
In stock
10.70
8.84 € Without VAT
pluss minuss
AKVILON
In stock
11.56
9.55 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
20.81
17.20 € Without VAT
pluss minuss
Bend 90° - D-80
code: dvlv90080
AKVILON
In stock
29.69
24.54 € Without VAT
pluss minuss
AKVILON
In stock
32.66
26.99 € Without VAT
pluss minuss
AKVILON
In stock
37.11
30.67 € Without VAT
pluss minuss
Bend 45° - D-80
code: dvlv45080
AKVILON
In stock
18.82
15.55 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
28.50
23.55 € Without VAT
pluss minuss
Bend 30° - D-80
code: dvlv30080
AKVILON
In stock
16.99
14.04 € Without VAT
pluss minuss
Bend 15° - D-80
code: dvlv15080
AKVILON
In stock
16.99
14.04 € Without VAT
pluss minuss
AKVILON
In stock
39.95
33.02 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
36.58
30.23 € Without VAT
pluss minuss
Chimney Rain Cap - D-80
code: dvjv0080
AKVILON
In stock
23.04
19.04 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
50.70
41.90 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
134.31
111.00 € Without VAT
pluss minuss
AKVILON
In stock
106.55
88.06 € Without VAT
pluss minuss
AKVILON
In stock
11.87
9.81 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
19.02
15.72 € Without VAT
pluss minuss
AKVILON
In stock
AKVILON
In stock
AKVILON
In stock
11.76
9.72 € Without VAT
pluss minuss
AKVILON
In stock
11.76
9.72 € Without VAT
pluss minuss
AKVILON
In stock
11.10
9.17 € Without VAT
pluss minuss
AKVILON
In stock
9.17
7.58 € Without VAT
pluss minuss
AKVILON
In stock
9.66
7.98 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
19.66
16.25 € Without VAT
pluss minuss
AKVILON
production 2-7 working days
9.08
7.50 € Without VAT
pluss minuss
Wide locking clamp - D-80
code: dvsvp080
AKVILON
production 2-7 working days
10.02
8.28 € Without VAT
pluss minuss
Flue draught regulator - D-80
code: dvvrrco0080
AKVILON
delivery: 5-10 working days
72.48
59.90 € Without VAT
pluss minuss
AKVILON
delivery: 5-10 working days
7.83
6.47 € Without VAT
pluss minuss
delivery: 5-10 working days
63.16
52.20 € Without VAT
pluss minuss
production 2-7 working days
AKVILON
In stock
Renofast round single-wall chimney system diagram

Renofast round single-wall chimney system diagram

Round Single-Wall Chimneys RENOFAST

Single-wall round chimney systems are the fundamental element of modern chimney technology. They are used for connecting heating appliances to the main chimney, creating ventilation ducts, and for lining (relining) existing brick shafts.

SIA Akvilon manufactures RENOFAST 200, RENOFAST 600, and RENOFAST 600 Plus systems at its own production facility in Riga. We use industrial laser and plasma metal cutting, as well as robotic TIG welding. Thanks to the socket connection system, assembly is fast and precise. All elements are certified according to the European standard EN 1856-2 and correspond to temperature class T200 and T600.

Advantages of buying from us

  • Direct from the manufacturer: You work directly with us, receiving a fair price without intermediary markups.
  • In stock: We maintain a constant stock of key items. You don’t need to wait for weeks — you can come and purchase immediately.
  • Convenient logistics: Arrange fast delivery (across Latvia and the EU) or pick up your order from our warehouse in Riga.
  • Standard EN 1856-2: The CE marking confirms that the products have undergone factory production control and are safe for operation.

If you require installation, we also provide professional chimney lining services.

Advantages of the Round Section

The round shape of the pipe is optimal for smoke extraction from an aerodynamic perspective:

  • Efficient Draft: Flue gases move in a spiral as they rise. In a round channel, the flow meets no resistance from corners, minimizing turbulence.
  • Clean Channel: The absence of corners prevents the formation of stagnant zones where soot usually accumulates. Smooth walls and a round shape significantly simplify the mechanical cleaning process.
  • Structural Rigidity: A round pipe possesses natural geometric rigidity, making it resistant to thermal deformations.

Materials: Which Steel Grade to Choose?

The durability of the system directly depends on matching the steel grade to the operating conditions. We offer three versions:

RENOFAST 600 (AISI 304 / 304L)

The base solution made of classic chromium-nickel stainless steel. The main stock standard.

  • Application: Pellet (granule) boilers (optimal choice), wood stoves, fireplaces, sauna heaters, gas boilers, ventilation.
  • Properties: The steel possesses high heat resistance and excellent corrosion resistance in the environment created by burning pellets and wood.

RENOFAST 600 Plus (AISI 316L)

Acid-resistant execution. The steel is alloyed with molybdenum (2-3%), which enhances its chemical resistance.

  • Application: Diesel boilers, specific industrial facilities, systems with high condensate acidity.
  • Properties: Molybdenum ensures the metal's resistance to aggressive acids. Recommended for liquid fuel equipment.

RENOFAST T200 (With Seals)

A specialized airtight system, elements of which are equipped with grooves for heat-resistant silicone rings.

  • Application: Modern gas and condensing boilers working under positive pressure.
  • Properties: The presence of seals ensures the highest gas tightness class (P1) and guarantees 100% protection against condensate leaks even under pressure.

Technical Specifications

Parameter RENOFAST 600 RENOFAST 600 Plus RENOFAST T200
Material Stainless Steel
AISI 304/304L
Stainless Steel
AISI 316L
Stainless Steel
AISI 304
Wall Thickness 0.5 / 0.6 / 0.8 / 1.0 mm 0.5 / 0.6 mm
Working Temperature T600 (up to 600°C) T200 (up to 200°C)
Connection Type Socket, no gaskets Socket + Seal
Seam Welding Robotic seam TIG welding

Important Installation Aspects

"Condensate" Assembly
The socket design implies assembly where the upper pipe is inserted into the lower one. This is critical: condensate must flow down the inner wall of the pipe without entering the joints or the outer surface of the chimney.

Connecting to Ceramic Chimneys
When connecting a metal pipe to a ceramic shaft inlet (Schiedel, Tona, etc.), a special adapter with a soft seal must be used. Direct embedding of metal into ceramic using cement or rigid sealants is prohibited — thermal expansion of the steel can lead to the destruction of the ceramic tee.

Fire Safety
A single-wall pipe is a source of thermal radiation. During installation, safe distances to combustible structures (wood, drywall, wallpaper) must be observed — at least 500 mm. For outdoor installation and passing through ceilings/roofs, double-wall insulated chimneys should be used.

Diameter Calculation
The chimney diameter is selected based on the boiler power and pipe height. It is not recommended to narrow the chimney cross-section relative to the heating appliance outlet without a preliminary aerodynamic calculation.